R EDUCED W ATER F LOW
> 1cm
Ensure that the Venturi Intake is firmly connected to the Pump and is not blocked by any objects over or inside it.
Ensure that the venturi intake is positioned more than 1cm away from any walls or obstructions in the sump.
Disassemble and clean pump as described in “Pump Maintenance” on page 10
N O W ATER F LOW AT ALL
>1cm
Check that all connectors are securely connected and that power is connected and switched on.
Ensure that the venturi intake is positioned more than 1cm away from any walls or obstructions in the sump and is not clogged.
Disassemble and clean pump as described in “Pump Maintenance” on page 10.
Ensure that your hands are dry before touching the power point.
Hold the i m p e l l e r assembly by the disc. Turn the impeller by the magnet. It should spin smoothly - if
The only part of the impeller that should
To test the electric coil in the pump, remove the impeller. Plug the pump in (Ensure everything is
turn is the disc. If any other part turns independantly, the impeller is damaged and needs replacement
you feel any resistance or if it feels like it’s catching on something, the impeller may be worn and need replacement.
dry first!) and hold the impeller magnet next to the pump as shown. You should feel the magnet vibrate.